headerimage

NCS

Pressure transmitters with thick film strain gauge

 

Service intended: Relative and absolute pressure measurement of gaseous and liquid media, the flush diagram type also for highly viscous and crystallizing pressure media.

According to directive 97/23/EG.
 

Digital pressure transmitter DCS

hr
Downloads

Technical Details
Operation Manual

 

Technical Data
Case
Stainless steel 304S
Degree of protection
IP 65 per EN 60529 / IEC 529
Pressure connection
Stainless steel 316Ti
G1/2B per EN 837-1
G3/4B with flush diaphragm
G1/4 female
Sensing element
Ceramic diaphragm,
Measurig bridge, thick film strain gauge
Pressure and overpressure ranges
see Technical Details page 05.0308
Electrical connection
L-plug EN175301-803 Form A
Signal output1)                      Power supply
4 ... 20 mA, 2-wire         Ub = 7,5 ... 30 V DC
Load: Rb [ Ohm ] : ( Ub [ V ]-7,5 [ V ] )/0,025 [ A ]   
0 ... 10 V, 3-wire             Ub = 12 ... 30 V DC
Load: >10 kOhm
Ratiometric 0,5 ... 5,5 V
Load: >4,5 kOhm
Response time
t < 10 ms
Power consumption
P max = 0,75 W
EMC-Directive
2004/108/EC EN 61326 Emission (Group 1, Class B. Immunity, industrial locations)
Permissible temperatures Tmin / Tmax
Storage temperature  - 40 ... +100 °C
Medium temperature   - 25 ... +  80 °C
Ambient temperature  - 20 ... +  70 °C
Accuracy
Linearity + hysteresis + repeatability
FS see table on page 05.0312, < 0,5%BFSL
Temperature error
Mean TK of zero < 0,2 % FS / 10 K
Mean TK of range < 0,2 % FS / 10 K
Weight: 0,27 kg
Optional extras
see Technical Details page 05.0315
1)Digital indicator