headerimage

RT100

Room/outside resistance thermometers Pt100

Service intended: Particularly suitable for room temperature.
 

 

hr
Downloads

Technical Details
Operation Manual Pt100
Operation Manual Pt100 external

Technical Data
Protection class
see Technical Details page 11.3002
Temperature element
Measurement resistance Pt100 per DIN EN 60751
Load Pt100
0,3 ... 1,0 mA
Temperature range Tmin / Tmax
- 20 ... + 100°C
Accuracy class

Class A per DIN EN 60751, ±(0,15 + 0,002 °C x |t|)

Class B per DIN EN 60751, ±(0,3 + 0,005 °C x |t|)

Output signal
MU310 = 4 - 20 mA